WEBINAR
Share:

FDA Inspections Under QMSR: What Changes for Risk Management, CAPA, MDRs, and Design Controls

Course is now LIVE. Click below to join the session.

This course helps device organizations prepare for QMSR inspections by connecting risk management, CAPA, MDRs, Design Change Control, management responsibility, and supporting quality systems to FDA’s process-focused inspection approach.

/* Hide default + / - icon */ .accordion-toggle-icon { opacity: 0; } /* Add circle instead */ .accordion-header::after { content: "○"; font-size: 18px; margin-left: auto; transition: 0.2s ease; } /* When open → filled circle */ .accordion-item.active .accordion-header::after { content: "●"; } /* Hide default + / - icon */ .accordion-toggle-icon { opacity: 0; } /* Add circle instead */ .accordion-header::after { content: "○"; font-size: 18px; margin-left: auto; transition: 0.2s ease; } /* When open → filled circle */ .accordion-item.active .accordion-header::after { content: "●"; } .accordion-header::after { content: "◯"; font-size: 18px; transition: transform 0.25s ease; } .accordion-item.active .accordion-header::after { transform: rotate(90deg); }
REGISTRATION OPTIONS

Live session Plus
Complimentary 30 Days Streaming access

$290  |  One participant (viewer)

$390  |  Team (2 - 5 participants)

$490 |  Team (6 - 10 participants)

REGISTER FOR THE COURSE

US $290 per learner

30-Days Unlimited Streaming Access

/* Hide default + / - icon */ .accordion-toggle-icon { opacity: 0; } /* Add circle instead */ .accordion-header::after { content: "○"; font-size: 18px; margin-left: auto; transition: 0.2s ease; } /* When open → filled circle */ .accordion-item.active .accordion-header::after { content: "●"; } /* Hide default + / - icon */ .accordion-toggle-icon { opacity: 0; } /* Add circle instead */ .accordion-header::after { content: "○"; font-size: 18px; margin-left: auto; transition: 0.2s ease; } /* When open → filled circle */ .accordion-item.active .accordion-header::after { content: "●"; } .accordion-header::after { content: "◯"; font-size: 18px; transition: transform 0.25s ease; } .accordion-item.active .accordion-header::after { transform: rotate(90deg); }

REGISTER FOR THE COURSE

To Get 30-Day Access to ONLY this Course 

US $290 per learner
  • This course is Included in Subscription Pack
Subscription include access to entire Learning Library
/* Hide default + / - icon */ .accordion-toggle-icon { opacity: 0; } /* Add circle instead */ .accordion-header::after { content: "○"; font-size: 18px; margin-left: auto; transition: 0.2s ease; } /* When open → filled circle */ .accordion-item.active .accordion-header::after { content: "●"; } /* Hide default + / - icon */ .accordion-toggle-icon { opacity: 0; } /* Add circle instead */ .accordion-header::after { content: "○"; font-size: 18px; margin-left: auto; transition: 0.2s ease; } /* When open → filled circle */ .accordion-item.active .accordion-header::after { content: "●"; } .accordion-header::after { content: "◯"; font-size: 18px; transition: transform 0.25s ease; } .accordion-item.active .accordion-header::after { transform: rotate(90deg); }
  • Course ID
    TF3758
  • Live Q&A +
    Continued Learning
  • Presentation Handout
    & Templates
  • Assessment
    & Certification Included

 

Why take this course?

FDA’s Quality Management System Regulation (QMSR) changes the framework for medical device inspections by incorporating ISO 13485:2016 into 21 CFR 820 and moving beyond the former QSIT subsystem model. The new inspection approach places greater emphasis on process-focused assessment and patient or user risk management based on ISO 14971:2019, affecting how manufacturers demonstrate control across their quality management systems.


This webinar examines the QMSR inspection approach described in FDA Inspection Manual 7382.850 and the areas manufacturers should expect to receive increased attention. The discussion addresses risk management throughout the quality system, CAPA, Medical Device Reporting, Risk Files, Design Change Control documentation, implantable-device traceability, senior management responsibility, and quality culture. Participants will also consider the relationship between QMSR and ISO 13485, application across device classifications, combination products, and the supporting systems needed to demonstrate compliance under FDA’s process-focused inspection approach.

Prepare for the Shift From QSIT to Process-Focused Inspections

Understand how FDA’s inspection approach changes under QMSR and Inspection Manual 7382.850, including the move away from the former QSIT subsystem model. This perspective helps teams assess inspection preparation against interconnected quality processes rather than relying on practices developed around the previous inspection structure.

Strengthen Risk-Based Evidence Across the Quality System

Develop a clearer understanding of where patient and user risk management affects inspection exposure, including CAPA, MDRs, Risk Files, Design Change Control, and supporting systems. With ISO 14971 principles extending throughout the quality system, manufacturers need consistent evidence showing how risk considerations influence their quality activities and decisions.

Key Areas Covered

  • FDA QMSR Inspection Manual 7382.850 and the new inspection approach
  • Incorporation of ISO 13485:2016 into 21 CFR 820
  • ISO 14971:2019 risk management across the quality system
  • CAPA and Medical Device Reporting during QMSR inspections
  • Risk Files and Design Change Control documentation
  • Implantable-device traceability and supporting quality systems
  • Senior management responsibility and quality culture
  • QMSR considerations for device classifications and combination products

Who Must Attend

  • Senior management in Devices, Combination Products
  • Quality Assurance Departments
  • Regulatory Affairs Departments
  • Medical Device product development teams
  • Research and Development Departments
  • Engineering Departments
  • Production Departments
  • Operations Departments
  • Marketing Departments
  • Consultants; others tasked with device QA, product development, manufacturing, process / product / data analysis, regulatory submission responsibilities
If you would like to request a Proforma invoice to sign up for this course. please click here

Commonly Asked Questions About This Subject

The following questions address practical regulatory, compliance, validation, quality, operational, and inspection-related considerations commonly associated with this subject.

How can an FDA investigator determine whether risk management is actually influencing the quality system rather than existing mainly in the risk file?

The evidence appears in decisions made outside the risk management file. Complaint evaluations, CAPA investigations, supplier controls, process changes, design changes, acceptance activities, and post-market decisions should show that relevant product and patient risks were considered when those decisions were made.


Inspection friction develops when a manufacturer presents a well-maintained risk file but cannot connect it to current quality events. A serious complaint may reveal a hazardous situation that was never evaluated against existing risk assumptions. A CAPA may correct a recurring failure without considering whether occurrence estimates or risk controls require reassessment.


Investigators can follow those connections across records. If new field information emerges, they may ask where that information entered the risk management process and what changed as a result.


Strong evidence shows that risk information moves through the quality system when circumstances change. The risk file then reflects current operating experience rather than remaining primarily a design-stage artifact.

What makes a CAPA investigation vulnerable when the immediate correction is effective but the underlying risk assessment remains unchanged?

An effective correction can still leave a significant inspection question unanswered: did the event reveal anything new about the device's risk profile or the effectiveness of existing controls? CAPA records become vulnerable when that question was never evaluated.


Consider a recurring component failure that is successfully corrected through a supplier or manufacturing change. Closing the CAPA based on reduced recurrence may appear reasonable. If the failures exposed a hazardous situation, weakened an existing risk control, or occurred more frequently than assumed, the associated risk analysis may also require review.


FDA investigators can trace the event beyond the CAPA record into complaints, design information, post-market data, and risk documentation. Disconnected conclusions become visible quickly.


A defensible CAPA shows whether the investigation affected existing risk assumptions and documents the basis for that determination. Where no risk file change is warranted, the reasoning should still be evident rather than inferred from the absence of an update.

How should manufacturers handle complaints that do not meet MDR reporting criteria but repeatedly involve the same potential safety issue?

Repeated non-reportable complaints still require meaningful evaluation because the MDR decision answers only whether a particular event meets reporting requirements. A pattern of events can reveal information about product performance, risk controls, or failure mechanisms even when individual complaints remain below the reporting threshold.


A difficult inspection position develops when every complaint contains a defensible non-reportability decision but nobody has examined the cumulative pattern. Investigators may compare complaint codes, failure descriptions, service records, returned product findings, CAPAs, and risk documentation to determine whether the manufacturer recognized an emerging safety signal.


Consistency also matters. Similar events should not produce materially different MDR decisions without a clear reason.


Strong complaint governance therefore preserves the reasoning behind individual reporting decisions while ensuring recurring events are evaluated collectively. If the pattern changes the understanding of severity, occurrence, detectability, or control effectiveness, that information should reach the appropriate quality and risk processes rather than remain isolated inside complaint records.

What design change records are most likely to create problems when FDA traces a change from field experience back through the quality system?

Records become difficult to defend when they document what was changed but provide little evidence of why the change was sufficient. FDA may begin with a complaint or CAPA and trace backward into risk management, design changes, verification, validation, and regulatory assessments.


A design change prompted by field experience deserves particular attention because the original problem establishes context for judging the adequacy of the response. If a component, software function, labeling element, or risk control was modified, investigators may ask whether all affected requirements and hazards were identified, whether verification addressed the actual failure mechanism, and whether existing products or configurations were considered.


Weak change records often contain approvals and completed testing but leave these relationships implicit.


A stronger record allows an investigator to follow the sequence from observed problem to risk assessment, design decision, implementation, objective evidence, and post-change evaluation. That continuity demonstrates that the manufacturer controlled the quality issue across the system rather than closing it within one departmental workflow.

Your TalkFDA Webinar Experience

When you reserve your seat, everything is organized for you — from access to certification from one place.

1. Confirmation

You receive a confirmation email and your course appears instantly in your TalkFDA dashboard.

2. Your Course Hub
Your TalkFDA course page becomes your central hub where you can join the session, access materials, and manage your learning.

3. Join the Live Training
At the scheduled time, click Join Session and you’ll be connected to the live Webex session with the instructor.

4. Watch Again Anytime
After the session, the playback becomes available on the same course page so you can revisit important sections.
5. Earn Your Certificate
Complete the course and your certificate is unlocked automatically in your learning history.

Everything related to your webinar: access, materials, playback, and certification — lives in one place.
Simple. Organized. Professional.
Go ahead and reserve your seat with confidence.

Built on 20+ years of global regulatory training experience across FDA, EMA, MHRA, and ICH frameworks.
Trusted by professionals across 80+ countries.

Testimonials

This is an upcoming session. Feedback below reflects experiences from similar programs delivered by our expert faculty.

“Session was easy to follow even for non-core team members. That helped.”
- Production Officer
“Good balance. Not too basic, not too deep. Worked well for mixed team.”
- Manager, Regulatory Affairs
“Team found it useful. Especially for aligning understanding across functions.”
- Director, Operations

Ready to Strengthen Your Team? Let’s Build Your Training Plan.

Whether you’re looking for a single onsite workshop or a multi-team training series, we’ll help you design a program that fits your goals, timelines, and operational reality.

Your team deserves the clarity.
Your organization deserves the confidence.

Upcoming Courses

Featured Courses